Brocade Fabric OS Command Reference Manual (53-1000240-01, November 2006)

2-226 Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
filterTest
2
Note: Enter commands in lowercase only; mixed case is for readability.
Operands This command has the following operands:
--slot slotnumber Specify the slot number on which the diagnostic operates. The port specified are
relative to this slot number. The default is 0 and designed to operate on fixed-port-
count products.
-passcnt passcnt Specify the number of times to perform this test. The default value is 1.
-txports itemlist Specify the user port numbers to perform this test. All user ports are set by default.
-scamoff offset Specify the program location to write SCAM test data in SCAM memory. The
default value is 0. The maximum offset number is set if the specified number is
larger than the limit.
-dcamoff offset Specify the program location to write DCAM test data in DCAM memory. The
default value is 0. The maximum offset number is set if the specified number is
larger than the limit.
-fdefoff offset Specify the program location to write filter test definition data in filter definition
memory. The default value is 0. The maximum offset number is set if the specified
number is larger than the limit.
Examples To run a frame filter test:
Diagnostics When it detects failures, the subtest might report one or more of the following error messages:
DIAG-ACTTEST
DIAG-FLTINIT
DIAG-FLTRCV
DIAG-FLTXMIT
DIAG-NUMTEST
Refer to the Fabric OS Message Reference for more information.
See Also itemList
switch:admin> filtertest -txports 3/1-3/3
Running filtertest ..............
Test Complete: filtertest Pass 1 of 1
Duration 0 hr, 0 min & 2 sec (0:0:2:679).
passed.