Brocade Fabric OS Command Reference Manual (53-1000240-01, November 2006)

Fabric OS Command Reference Manual 2-251
Publication Number: 53-1000240-01
fwFruCfg
2
Note: Enter commands in lowercase only; mixed case is for readability.
fwFruCfg
Displays or modifies FRU state alert configuration.
Synopsis fwfrucfg [--show]
Description Use this command to configure FRU states and actions. Based on these configuration settings, Fabric
Watch generates action when an FRU state changes. To configure email alerts, use fwMailCfg.
N
ote
This command requires a Fabric Watch license.
The command is not applicable to platforms without FRUs.
N
ote
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands This command has the following operand:
--show Displays the current FRU configuration setting.
If no operand is specified, the configuration prompt displays.
Examples To change FRU state alert configuration:
See Also fwConfigure, fwMailCfg
switch:admin> fwfrucfg
The current FRU configuration:
Alarm State Alarm Action
-----------------------------------------------
Slot 0 1
Power Supply 0 0
Fan 0 0
WWN 0 0
Note that the value 0 for a parameter means that
it is NOT used in the calculation
Configurable Alarm States are:
Absent-1, Inserted-2, On-4, Off-8, Faulty-16
Configurable Alarm Actions are:
Errlog-1, E-mail-16
Slot Alarm State: (0..31) [0] 3
Slot Alarm Action: (0..17) [1]
Power Supply Alarm State: (0..31) [0]
Power Supply Alarm Action: (0..17) [0]
Fan Alarm State: (0..31) [0]
Fan Alarm Action: (0..17) [0]
WWN Alarm State: (0..31) [0]
WWN Alarm Action: (0..17) [0]
Fru configuration successfully changed