Brocade Fabric OS Command Reference Manual (53-1000240-01, November 2006)

Fabric OS Command Reference Manual 2-309
Publication Number: 53-1000240-01
iscsiPortCfg
2
Note: Enter commands in lowercase only; mixed case is for readability.
iscsiPortCfg
Displays or modifies iSCSI port parameters.
Synopsis iscsiportcfg --clearstats slot/geport
iscsiportcfg --default slot/geport
iscsiportcfg --show slot/geport [-v]
iscsiportcfg --modify slot/geport options
Description Use this command to display or modify the iSCSI port parameters.
The following table lists the default iSCSI port settings.
Setting Default
Error recovery level 0
Connections per session 1
Data digest support Disabled
Header digest support Disabled
Immediate data support No
First burst length value 512
N
ote
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands This command has the following operands:
--modify Modifies the port parameters on the specified port. Valid options are:
-e value
Specifies the error recovery level; values are 0, 1, or 2.
-c value
Specifies the number of connections per sessions; values are 1 or 2.
-d value
Enables or disables data digest support; specify 0 to disable or 1 to enable.
-a value
Enables or disables header digest support; specify 0 to disable or 1 to enable.
-i value
Enables or disables immediate data support; specify 0 to disable or 1 to
enable.
-f value
Specifies the first burst length value; values include 512, 1024, 2048, 4096,
8192, 16384, and 32768.
--clearstats Clears port-level iSCSI statistics on the specified port.
--default Resets the port to the default values. See the "Description" section for the list of
default values.