Brocade Fabric OS Command Reference Manual (53-1000240-01, November 2006)

Fabric OS Command Reference Manual 2-421
Publication Number: 53-1000240-01
perfShowPortEEMask
2
Note: Enter commands in lowercase only; mixed case is for readability.
perfShowPortEEMask
Displays the current address mask for end-to-end performance monitors on a port.
Synopsis perfshowporteemask [slotnumber/]portnumber
Description Use this command to display the current mask shared across all end-to-end (EE) performance monitors
of a port. There are only two commands that can modify the value of the EE mask: perfSetPortEEMask
and perfCfgRestore.
The end-to-end mask has 12 fields:
TxSID Domain: on
TxSID Area: on
TxSID ALPA: on
TxDID Domain: on
TxDID Area: on
TxDID ALPA: on
RxSID Domain: on
RxSID Area: on
RxSID ALPA: on
RxDID Domain: on
RxDID Area: on
RxDID ALPA: on
The fields that are marked “on” are used to trigger end-to-end monitors. The default value of the EE mask
is all fields set to “on.”
N
ote
This command requires a Brocade Advanced Performance Monitoring license.
This command is deprecated; use perfMonitorShow instead.
This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE
ports.
N
ote
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands This command has the following operand:
slotnumber For bladed systems only, this operand specifies the slot number of the port on
which the monitor is to be displayed, followed by a slash (/).
portnumber Specifies the number of the port on which the monitor is to be displayed, relative
to its slot for bladed systems. Use switchShow for a list of valid ports.