portCfgDefault
2
Note: Enter commands in lowercase only; mixed case is for readability.
portCfgDefault
Restores the port configuration to factory default values.
Synopsis portcfgdefault [slotnumber/][ge]portnumber
Description Use this command to reset any special configuration values on a port to their factory defaults. This
command will disable ports capable of routing persistently, which is the factory default value. You can
view the current port configuration using the portCfgShow command.
This command does not change the state of a port. To make an E_Port go back to the online state, use
either switchDisable/switchEnable or portDisable/portEnable.
N
ote
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands This command has the following operands:
slotnumber For bladed systems only, specify the slot number of the port to display, followed
by a slash (/).
portnumber Specify the number of the port to be returned to default values, relative to its slot
for bladed systems. Use switchShow to list valid ports.
Examples To reset a port to factory defaults:
To reset a GbE port to factory defaults:
See Also portCfgEPort, portCfgGPort, portCfgLongDistance, portCfgLPort, portCfgPersistentDisable,
portCfgPersistentEnable, portCfgShow, portCfgSpeed, portCfgTrunkPort
switch:admin> portcfgdefault 1/3
switch:admin> portcfgdefault 8/ge1