Brocade Fabric OS Command Reference Manual (53-1000240-01, November 2006)

Fabric OS Command Reference Manual 2-451
Publication Number: 53-1000240-01
portCfgLongDistance
2
Note: Enter commands in lowercase only; mixed case is for readability.
Operands This command has the following operands:
slotnumber Specifies the slot number, for bladed systems only. The slot number must be
followed by a slash (/).
portnumber Specifies a port number. Valid values for port number vary, depending on the
switch type. Use switchShow to display a list of valid ports. This operand is
required.
distance_level Refer to the “Description” section for information about the value.
vc_translation_link_init
Specifies the long-distance link-initialization sequence; 1 activates and 0
deactivates this mode. When the command is run without specifying a value, 1 is
assigned automatically for the long-distance link in VC_RDY flow control;
otherwise, 0 is assigned. This operand is optional.
desired_distance Refer to the “Description” section for information about the value.
Examples To configure a switch port 63 to support a 100 Km link and be initialized using long-distance link
initialization protocol:
See Also configure, portCfgISLMode, portCfgTrunkPort, portCfgShow, portShow, switchShow
switch:admin> portcfglongdistance 4/15 LS 1 100
switch:admin> portshow 4/15
portCFlags: 0x1
portFlags: 0x20001 PRESENT LED
portType: 1.1
portState: 2 Offline
portPhys: 4 No_Light
portScn: 0
portId: 013f00
portWwn: 20:3f:00:60:69:00:02:48
Distance: super long <= 100km
portSpeed: 2Gbps
Interrupts: 9 Link_failure: 0 Frjt: 0
Unknown: 0 Loss_of_sync: 0 Fbsy: 0
Lli: 9 Loss_of_sig: 9
Proc_rqrd: 0 Protocol_err: 0
Timed_out: 0 Invalid_word: 0
Rx_flushed: 0 Invalid_crc: 0
Tx_unavail: 0 Delim_err: 0
Free_buffer: 0 Address_err: 0
Overrun: 0 Lr_in: 0
Suspended: 0 Lr_out: 0
Parity_err: 0 Ols_in: 0
2_parity_err: 0 Ols_out: 0
CMI_bus_err: 0