Brocade Fabric OS Command Reference Manual (53-1000240-01, November 2006)

2-526 Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
portStatsShow
2
Note: Enter commands in lowercase only; mixed case is for readability.
N
ote
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands This command has the following operands:
slotnumber For bladed systems only, specifies the slot number of the port to be displayed,
followed by a slash (/).
[ge]portnumber Specifies a port number to be configured, relative to its slot for bladed systems.
Specify the optional ge option to display the GbE port hardware statistics. Use
switchShow to display a list of valid ports.
ge Displays the GbE statistics.
ip Displays all the GbE port statistics related to IP addresses that are on (not zero).
Optionally, use ipaddress to display statistics for the specified IP address.
fcip Displays the GbE statistics on all FCIP tunnels. Optionally, use tunnelnumber to
display statistics for the specified FCIP tunnel.
er_zone_discard
Class 3 frames discarded due to zone mismatch.
er_crc_good_eof
CRC error with good EOF (platform and port specific).
er_inv_arb
Invalid ARB.
open
Number of times the FL_Port entered OPEN state.
transfer
Number of times the FL_Port entered TRANSFER state.
opened
Number of times the FL_Port entered OPENED state.
starve_stop
Loop tenancies stopped due to starvation.
fl_tenancy
Number of times FL_Port had loop tenancy.
nl_tenancy
Number of times NL_Port had loop tenancy.
zero_tenancy
Number of times zero tenancy occurred.