Brocade Fabric OS Command Reference Manual (53-1000240-01, November 2006)

Fabric OS Command Reference Manual 2-541
Publication Number: 53-1000240-01
psShow
2
Note: Enter commands in lowercase only; mixed case is for readability.
psShow
Displays power supply status.
Synopsis psshow
Description Use this command to display the current status of the switch power supplies.
The status of each supply is displayed as:
OK Power supply functioning correctly.
absent Power supply not present.
unknown Unknown power supply unit installed.
predicting failure Power supply is present but predicting failure.
faulty Power supply present but faulty (no power cable, power switch turned off, fuse
blown, or other internal error).
For certain switch models, the OEM serial ID data displays after each power supply status line.
N
ote
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands none
Examples To view the status of the power supplies:
See Also chassisShow, fanShow
switch:admin> psshow
Power Supply #1 is OK
DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000088
Power Supply #2 is faulty
DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000162
Power Supply #3 is OK
DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000120
Power Supply #4 is absent