Brocade Fabric OS Command Reference Manual (53-1000240-01, November 2006)

2-616 Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
slotPowerOff
2
Note: Enter commands in lowercase only; mixed case is for readability.
slotPowerOff
Removes power from a slot.
Synopsis slotpoweroff slotnumber
Description Use this command to turn off the power to a blade unit. The slot must have a valid blade unit present and
the blade unit must be of a type that can be powered off.
N
ote
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands This command has the following operand:
slotnumber Specify the slot number of the blade to be powered down. This operand is
required.
Examples To power off blade unit 3:
See Also powerOffListSet, powerOffListShow, slotPowerOn, slotShow
switch:admin> slotpoweroff 3