slotShow
2
Note: Enter commands in lowercase only; mixed case is for readability.
The blade is present, powered on, and running the preboot power on self
tests).
INITIALIZING
The blade is present, powered on, and initializing hardware components.
ENABLED
The blade is on and enabled.
ENABLED (User Ports Disabled)
The blade is on but the external ports are disabled using bladeDisable.
•DISABLED
The blade is powered on but disabled.
FAULTY
The blade is faulty because an error was detected.
UNKNOWN
The blade is inserted but its state cannot be determined.
N
ote
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands none
Examples To display the status of all slots in the system:
See Also bladeDisable, bladeEnable, chassisShow, slotPowerOff, slotPowerOn
switch:user> slotshow
Slot Blade Type ID Status
---------------------------------
1 SW BLADE 2 FAULTY
2 SW BLADE 2 DISABLED
3 SW BLADE 2 ENABLED
4 SW BLADE 2 DIAG RUNNING POST2
5 CP BLADE 1 ENABLED (User Ports Disabled)
6 CP BLADE 1 ENABLED
7 AP BLADE 24 LOADING
8 SW BLADE 2 DIAG RUNNING POST1
9 SW BLADE 2 INSERTED, NOT POWERED ON