Brocade Fabric OS Command Reference Manual (53-1000240-01, November 2006)
Fabric OS Command Reference Manual 2-619
Publication Number: 53-1000240-01
slotShow
2
Note: Enter commands in lowercase only; mixed case is for readability.
The blade is present, powered on, and running the preboot power on self
tests).
• INITIALIZING
The blade is present, powered on, and initializing hardware components.
• ENABLED
The blade is on and enabled.
• ENABLED (User Ports Disabled)
The blade is on but the external ports are disabled using bladeDisable.
•DISABLED
The blade is powered on but disabled.
• FAULTY
The blade is faulty because an error was detected.
• UNKNOWN
The blade is inserted but its state cannot be determined.
N
ote
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands none
Examples To display the status of all slots in the system:
See Also bladeDisable, bladeEnable, chassisShow, slotPowerOff, slotPowerOn
switch:user> slotshow
Slot Blade Type ID Status
---------------------------------
1 SW BLADE 2 FAULTY
2 SW BLADE 2 DISABLED
3 SW BLADE 2 ENABLED
4 SW BLADE 2 DIAG RUNNING POST2
5 CP BLADE 1 ENABLED (User Ports Disabled)
6 CP BLADE 1 ENABLED
7 AP BLADE 24 LOADING
8 SW BLADE 2 DIAG RUNNING POST1
9 SW BLADE 2 INSERTED, NOT POWERED ON
10 UNKNOWN VACANT