Brocade Fabric OS Command Reference Manual (53-1000240-01, November 2006)

2-674 Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
switchShow
2
Note: Enter commands in lowercase only; mixed case is for readability.
sw shortwave laser
lw longwave laser
cu copper
id serial ID
Speed The speed of the port:
1/8G 125 Mbit/sec
1/4G 250 Mbit/sec
1/2G 500 Mbit/sec
1G 1 Gbit/sec fixed transfer speed
N1 1 Gbit/sec negotiated transfer speed
2G 2 Gbit/sec fixed transfer speed
N2 2 Gbit/sec negotiated transfer speed
4G 4 Gbit/sec fixed transfer speed
N4 4 Gbit/sec negotiated transfer speed
AN Auto negotiating
UN Unknown
Port State Port state information:
No_Card
No interface card present.
No_Module
No module (GBIC or other) present.
Mod_Val
Module validation in process.
Mod_Inv
Invalid module.
No_Light
Module not receiving light.
No_Sync
Module receiving light but out of sync.
In_Sync
Module receiving light and in sync.
Laser_Flt
Module signaling a laser fault.
Port_Flt
Port marked faulty.
Diag_Flt
Port failed diagnostics.
Lock_Ref
Locking to the reference signal.