burninErrClear
2
Note: Enter commands in lowercase only; mixed case is for readability.
burninErrClear
Clears errors stored in the nonvolatile memory on the slot during burn-in.
Synopsis burninerrclear slotnumber
Description Use this command to clear errors stored in the nonvolatile memory on the slot during burn-in.
N
ote
It is advisable to run the burninErrClear command prior to running diagSetBurnin and diagSetCycle.
N
ote
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands The operand is a follows:
slotnumber A nonzero value that specifies the slot number from which to clear burn-in errors.
Examples To clear burn-in errors from slot 2.
See Also burninErrShow