Brocade Fabric Watch Administrator's Guide v6.1.0 (53-1000601-02, June 2008)

Fabric Watch Administrator’s Guide 19
53-1000601-02
Event Configuration
1
DRAFT: BROCADE CONFIDENTIAL
Figure 8 illustrates event notification using an In-Between event trigger. The arrow labeled 1
indicates the point at which event notification occurs.
FIGURE 8 In-between event trigger
Fabric Watch alarm behavior
Fabric Watch alarm behavior depends on the threshold states associated with the Above, Below
and Changed thresholds. Threshold states can be INFORMATIVE, IN_RANGE, and OUT_OF_RANGE.
Alarms are generated only for the following transitions:
IN_RANGE to OUT_OF_RANGE
OUT_OF_RANGE to IN_RANGE
No alarm is generated for INFORMATIVE to IN_RANGE (or IN_RANGE to INFORMATIVE)
See Appendix , “Default Threshold Values” for more details about the threshold states for Above,