Brocade Fabric Watch Administrator's Guide v6.1.0 (53-1000601-02, June 2008)

Fabric Watch Administrator’s Guide 35
53-1000601-02
Fabric Watch threshold configuration
3
Select threshold index => : (216..223) [216] 218
Index ThresholdName Port CurVal Status
LastEvent LasteventTime LastVal LastState
=============================================================================
216 eportRXPerf216 8/24 0 Percentage(%)/min enabled
inBetween Fri Oct 21 14:21:01 2005 0 Percentage(%)/min Informative
217 eportRXPerf217 8/25 0 Percentage(%)/min enabled
inBetween Fri Oct 21 14:21:07 2005 0 Percentage(%)/min Informative
218 eportRXPerf218 8/26 0 Percentage(%)/min enabled
inBetween Fri Oct 21 14:21:07 2005 0 Percentage(%)/min Informative
219 eportRXPerf219 8/27 0 Percentage(%)/min enabled
inBetween Fri Oct 21 14:21:07 2005 0 Percentage(%)/min Informative
220 eportRXPerf220 8/28 0 Percentage(%)/min enabled
inBetween Fri Oct 21 14:21:07 2005 0 Percentage(%)/min Informative
221 eportRXPerf221 8/29 0 Percentage(%)/min enabled
inBetween Fri Oct 21 14:21:07 2005 0 Percentage(%)/min Informative
222 eportRXPerf222 8/30 0 Percentage(%)/min enabled
inBetween Fri Oct 21 14:21:07 2005 0 Percentage(%)/min Informative
223 eportRXPerf223 8/31 0 Percentage(%)/min enabled
inBetween Fri Oct 21 14:21:07 2005 0 Percentage(%)/min Informative
Step 4. Advanced configuration
Table 12 describes the 18 customization options displayed at the end of the Advanced
Configuration menu. With the exception of the last option, which exits advanced configuration
mode, each option has similar behavior. For each option, one or two lines will appear, prompting
you to accept the new setting information, and, after the information has been provided, the entire
screen will refresh to display the updated information.
TABLE 12 Advanced Configuration options
Option Effect Input information
change behavior type Changes the behavior type of a single
element to either Triggered or
Continuous. The change is volatile
because this option is not saved to
flash memory. Every time the switch
is rebooted, this option is reset.
The element index and the required
behavior type
change behavior interval Changes the behavior interval for a
single element. The change is volatile
because this option is not saved to
flash memory. Every time the switch
is rebooted, this option is reset.
This value is effective only when the
behavior type is set to continuous.
The element index and the required
behavior interval, in seconds
change threshold boundary
level
Changes between the factory default
and custom threshold information.
The required threshold column
change custom unit Obsolete Obsolete
change custom time base Changes the time base for the area,
but only affects the custom column.
The required time base
change custom low Changes the low setting for the
threshold, but only affects the custom
column.
The required low threshold, in the units
defined by the area