Brocade Fabric Watch Administrator's Guide v6.1.0 (53-1000601-02, June 2008)

36 Fabric Watch Administrator’s Guide
53-1000601-02
Fabric Watch threshold configuration
3
NOTE
Not all areas allow for the customization of all fields. If you attempt an illegal modification, Fabric
Watch displays an error message. Ensure that all changes to the threshold and event setting areas
of the screen are confirmed before leaving advanced configuration, or the changes are lost.
change custom high Changes the high setting for the
threshold, but only affects the custom
column.
The required high threshold, in the units
defined by the area
change custom buffer Changes the buffer size for the
threshold, but only affects the custom
column.
The required buffer size, in the units
defined by the area
apply threshold boundary
changes
Confirms the changes made to the
threshold information. This must be
done to retain the changes made.
None
cancel threshold boundary
changes
Returns the boundary information to
the last confirmed state.
None
change threshold alarm level Changes between the factory default
and custom event settings for the
area.
The required event setting column
change changed alarm Changes the notification method for
changed event occurrences for this
method, but only affects the custom
column.
The required notification methods
change above alarm Changes the notification method for
above event occurrences for this
method, but only affects the custom
column.
The required notification methods
change below alarm Changes the notification method for
below event occurrences for this
method, but only affects the custom
column.
The required notification methods
change inBetween alarm Changes the notification method for
inBetween event occurrences for this
method, but only affects the custom
column.
The required notification methods
apply threshold alarm changes Confirms the changes made to the
event setting information. This must
be done to retain the changes made.
None
cancel threshold alarm
changes
Returns the event setting information
to the last confirmed state.
None
TABLE 12 Advanced Configuration options (Continued)
Option Effect Input information