Brocade Fabric Watch Administrator's Guide v6.1.0 (53-1000601-02, June 2008)

Fabric Watch Administrator’s Guide 39
53-1000601-02
Fabric Watch threshold configuration
3
Threshold boundary level is setat : Default
DefaultCustom
Unit Percentage(%) Percentage(%)
Time base minuteminute
Low 0 0
High 100 80
BufSize 0 0.
3. Type 3 at the Select choice => prompt to change the threshold boundary level, and then type 2
at the Enter boundary level type = > prompt to specify that this is a custom value, as shown in
the following system output.
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change belowalarm
4 : change custom unit 14 : change abovealarm
5 : change custom timebase 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18]3
1 : Default
2 : custom
Enter boundary level type => : (1..2) [1] 2
Index ThresholdName BehaviorType BehaviorInt
216 eportRXPerf216 Triggered 1
217 eportRXPerf217 Triggered 1
218 eportRXPerf218 Triggered 1
219 eportRXPerf219 Triggered 1
220 eportRXPerf220 Triggered 1
221 eportRXPerf221 Triggered 1
222 eportRXPerf222 Triggered 1
223 eportRXPerf223 Triggered 1
Threshold boundary level is set at : Custom.
4. Type 9 at the Select choice => prompt to apply the custom value.
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change belowalarm
4 : change custom unit 14 : change abovealarm
5 : change custom timebase 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18]9.
5. Type 16 at the Select choice => prompt to apply the changes.