Brocade Fabric Watch Administrator's Guide v6.1.0 (53-1000601-02, June 2008)

40 Fabric Watch Administrator’s Guide
53-1000601-02
Fabric Watch threshold configuration
3
6. Use the following commands to switch between custom and default values:
fwSetToCustom
Sets the boundary and alarm level to custom
fwSetToDefault
Restores the boundary and alarm level to the default
See Chapter 1, “Fabric Watch Concepts” for details about the event setting table and
notification methods for each of the possible event settings.
For details about advanced configuration menu options, see Table 12 on page 35.
Step 5. Alarm configuration
NOTE
The allowed alarm types are displayed on a per-class basis. Although Port Fencing is displayed for
other areas, such as RX Performance, for which Port Fencing is not supported, you will not be able
to set or apply changes on such areas.
Alarms act as a signal or alert that notifies you when a threshold has been crossed. You can
configure the following types of notification settings for Fabric Watch:
Triggered
A triggered behavior type signals you once after a threshold has been crossed. Triggered is the
default behavior type signal for all class areas.
Continuous
A continuous behavior type signals you continuously after a threshold has been crossed.
Changing the alarm for the RXPerformance class
You can change the above alarm for the RXPerformance class. The value is the sum of the alarm
matrix values; for example, PortFencing-32, SnmpTrap-2, and Errlog-1 (32+2+1=35).
1. Add the numbers beside each state that you want to include. The values for the states are:
Errlog - 1
SnmpTrap - 2
PortLogLock - 4
RapiTrap - 8
EmailAlert - 16
PortFencing - 32
2. Enter the total at the prompt.
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change belowalarm
4 : change custom unit 14 : change abovealarm
5 : change custom timebase 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18]14