Brocade Fabric Watch Administrator's Guide v6.1.0 (53-1000601-02, June 2008)

60 Fabric Watch Administrator’s Guide
53-1000601-02
Types of Fabric Watch reports
4
Switch status policy report
The switch status policy report displays the current policy parameter.
The following example of the switchStatusPolicyShow command output is for modular switches
such as the Brocade 48000. For modular switches, the switch status policy report also contains
information on the WWN, Blade, and CP.
For non-modular switches such as the Brocade 4100 and 5000, the WWN, Blade, CP, and core
blade information is not displayed.
Type the switchStatusPolicyShow command to generate a switch status policy report.
Example: Switch status policy report
The current overall switch status policy parameters:
Down Marginal
----------------------------------
PowerSupplies 2 1
Temperatures 2 1
Fans 2 1
WWN 0 1
CP 0 1
Blade 0 1
CoreBlade 0 1
Flash 0 1
MarginalPorts 2 1
FaultyPorts 2 1
MissingSFPs 0 0
Port detail report
If the switch health report shows marginal throughput or decreased performance, use the port
detail report to see statistics on each port. The port detail report is a Fabric Watch licensed
product. You can also see port details by health. For example, you can see only healthy ports, only
marginal ports, only faulty ports, or only offline ports.
The following is an example of a port detail report. An “X” in the column for a condition indicates
that the condition has exceeded the threshold.
NOTE
Port detail reports do not display the health status of GbE ports. Fabric Watch only monitors and
reports the status for physical and virtual FC ports.