Brocade Fabric Watch Administrator's Guide v6.1.0 (53-1000601-02, June 2008)

64 Fabric Watch Administrator’s Guide
53-1000601-02
Environment class
DRAFT: BROCADE CONFIDENTIAL
Environment class
Table 17 provides default Environment class settings for all switches. Check the appropriate
hardware reference manual for differences in actual environmental requirements.
NOTE
For the Brocade 200E, there is no fan default threshold because the fans are not monitored by
Fabric Watch. You can use the fanShow command to view the Brocade 200E fan status.
TABLE 17 Environment class threshold defaults
Area Description Default threshold settings Default alarm settings Threshold state
Fan Monitors switch fan
speed in RPMs
Unit: RPM
Time Base: none
Brocade 300
Low: 0
High: 40
Buffer: 10
Brocade 4100
Low: 3000
High: 12000
Buffer: 3
Brocade 4900
Low: 4100
High: 8500
Buffer: 3
Brocade 5000
Low: 3000
High: 12000
Buffer: 3
Brocade 5100
Low: 0
High: 35
Buffer: 10
Brocade 5300
Low: 0
High: 34
Buffer: 10
Brocade 7500
Low: 5000
High: 16000
Buffer: 3
Brocade 7600
Low: 5000
High: 16000
Buffer: 3
Brocade 48000
Low: 1600
High: 3400
Buffer: 3
Brocade DCX
Low: 800
High: 16000
Buffer: 3
Changed: 0
Above: 3
Below: 3
In-Between: 1
Informative
Out_of_range
Out_of_range
In_range