Brocade Fabric Watch Administrator's Guide v6.1.0 (53-1000601-02, June 2008)

Fabric Watch Administrator’s Guide 65
53-1000601-02
Environment class
DRAFT: BROCADE CONFIDENTIAL
Power Supply Monitors power supply
condition
Time Base: none
OK: 1
Faulty: 0
Changed: 0
Below: 3
Above: 3
In-Between: 0
Informative
Out_of_range
In_range
Informative
Temperature Monitors switch
temperature in Celsius
Unit: degrees C
Time Base: none
Brocade 200E
Low: 0
High: 60
Buffer: 10
Brocade 300
Low: 0
High: 40
Buffer: 10
Brocade 4100
Low:0
High: 60
Buffer: 10
Brocade 4900
Low: 0
High: 47
Buffer: 10
Brocade 5000
Low:0
High: 60
Buffer: 10
Brocade 5100
Low: 0
High: 35
Buffer: 10
Brocade 5300
Low: 0
High: 34
Buffer: 10
Brocade 7500
Low: 0
High: 63
Buffer: 10
Brocade 7600
Low: 0
High: 63
Buffer: 10
Brocade 48000
Low: 0
High: 60
Buffer: 10
Brocade DCX
Low: 0
High: 70
Buffer: 10
Changed: 0
Below: 3
Above: 3
In-Between: 3
Informative
Out_of_range
Out_of_range
In_range
TABLE 17 Environment class threshold defaults (Continued)
Area Description Default threshold settings Default alarm settings Threshold state