Brocade Fabric Watch Administrator's Guide v6.1.0 (53-1000601-02, June 2008)

68 Fabric Watch Administrator’s Guide
53-1000601-02
Port class
DRAFT: BROCADE CONFIDENTIAL
Port class
Table 22 provides default settings for areas in the Port class.
TABLE 22 Port class threshold defaults
Area Description Default threshold settings Default alarm settings Threshold state
Invalid CRC Count Monitors the
number of CRC
errors
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Invalid Transmission
Word
Monitors the
number of invalid
words transmitted
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Link Failure Count Monitors the
number of link
failures
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Loss of Signal Count Monitors the
number of signal
loss errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Loss of
Synchronization
Count
Monitors the
number of loss of
synchronization
errors
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Primitive Sequence
Protocol Error
Monitors the
number of primitive
sequence errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Receive Performance Monitors receive
rate, by percentage
Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
State Changes Monitors state
changes
Unit: Changes
Time Base: minute
Low:0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Transmit
Performance
Monitors
transmission rate,
by percentage
Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative