Configuring alarms for FRUs
12
Click Triggered to receive threshold alarms only when they are triggered by events that you
have defined.
Click Continuous to receive threshold alarms at a continuous interval. Select a time
interval in which to receive the threshold alarms from the Time Interval menu.
9. Click Apply.
10. Optional: Apply the selections on this panel to multiple elements simultaneously.
a. Click Apply More.
The Multiple Selection dialog box displays.
b. Click the boxes next to the indices of all applicable elements.
c. Click OK.
Configuring alarms for FRUs
Configuration for the FRU class is different than configuration for the other classes. Because FRUs
are not monitored through a threshold-based system, they have a simpler interface for
configuration. For FRUs, you configure the states for which an event occurs, as described in the
following procedure.
1. Open the Fabric Watch window.
2. Click the Threshold Configuration tab.
3. In Fabric Watch Explorer, click a FRU class.
4. Under Area Selection, choose a FRU type from the drop-down list.
5. Click the alarm states for which you want an event to register. Whenever a FRU of the selected
type is detected to be in one of the selected states, an event will occur.
6. Click the methods by which you want to be notified about the FRU alarms. For FRUs, the only
options are error log and email alert.
7. Cli ck Apply to apply the changes to the switch.
A confirmation dialog box displays, asking if you want to apply the changes to the switch.
8. Click OK in the confirmation dialog box to save the changes to the switch.