Fabric OS Documentation Updates Supporting Fabric OS v7.0.x

Table Of Contents
Fabric OS Documentation Updates 19
53-1002165-10
Chapter
5
Fabric OS Command Reference
In this chapter
Documentation Updates for Fabric OS v7.0.0 . . . . . . . . . . . . . . . . . . . . . . . . 19
Documentation Updates for Fabric OS v7.0.1 . . . . . . . . . . . . . . . . . . . . . . . . 27
Documentation Updates for Fabric OS v7.0.1.x. . . . . . . . . . . . . . . . . . . . . . . 31
Documentation Updates for Fabric OS v7.0.2 . . . . . . . . . . . . . . . . . . . . . . . . 35
Documentation Updates for Fabric OS v7.0.0
The updates in this section are for the Fabric OS Command Reference, publication number
53-1002147-01, published April 2011.
bottleneckMon
On page 74, add the error message ID (RAS Cx-1018) to the description of the credit recovery feature as
shown:
When used with the -recover onLrThresh option, recovery is attempted through repeated link resets
and a count of the link resets is kept. If the threshold of more than two link resets per hour is reached, the
blade is faulted (RAS Cx-1018). Note that regardless of whether the link reset occurs on the port blade or
on the core blade, the port blade is always faulted.
ceePortLoopbackTest/portLoopbackTest
The man pages and corresponding pages in the Command Reference should be updated with the
following note:
This diagnostic cannot be run on an operational switch. You must disable the switch using the
chassisDisable command before you can run this test. After the test completes, re-enable the switch
using the chassisEnable command. Do not use the switchDisable command followed by manually
shutting down the ports before running the test. This will not work because executing switchEnable after
the test completes will leave the ports in the same state as before. The only way to bring the ports down
before running the test and back up after the test completes is by using the chassisDisable command
followed by the chassisEnable command.