Fabric OS Documentation Updates Supporting Fabric OS v7.0.x
Table Of Contents
- Contents
- About This Document
- Access Gateway Administrator’s Guide
- CEE Administrator’s Guide
- CEE Command Reference
- Fabric OS Administrator’s Guide
- Documentation updates for Fabric OS v7.0.0 and later
- Chapter 2, Performing Basic Configuration Tasks
- Chapter 4, Routing Traffic
- Chapter 5, Managing User Accounts
- Chapter 6, Configuring Protocols
- Chapter 7, Configuring Security Policies
- Chapter 9, Installing and Maintaining Firmware
- Chapter 12, Traffic Isolation Zoning
- Chapter 18, Administering Licensing
- Chapter 19, Monitoring Fabric Performance
- Chapter 20, Optimizing Fabric Behavior
- Chapter 22, Managing Long Distance Fabrics
- Chapter 23, Using the FC-FC Routing Service
- Documentation updates for Fabric OS v7.0.1 and later
- Documentation updates for Fabric OS v7.0.0 and later
- Fabric OS Command Reference
- Fabric OS Encryption Guide Supporting LKM
- Fabric OS Encryption Guide Supporting RKM
- Fabric OS Encryption Guide Supporting SKM and ESKM
- Fabric OS Encryption Guide Supporting TEMS
- Fabric OS Encryption Guide Supporting TEMS
- Fabric OS FCIP Administrator’s Guide
- Fabric OS FICON Administrator’s Guide
- Fabric OS Message Reference
- Fabric OS MIB Reference
- Fabric OS Troubleshooting and Diagnostics Guide
- Fabric Watch Administrator’s Guide
- Web Tools Administrator’s Guide
- Brocade DCX Backbone Hardware Reference Manual
- Brocade DCX-4S Backbone Hardware Reference Manual
Fabric OS Documentation Updates 37
53-1002165-10
slotShow
5
EXAMPLES To enable SerDes tuning optimization on all backend ports and to display the configuration:
switch:admin> serdestunemode --autoset
Autotunemode is turned on
switch:admin> serdestunemode --show
Autotunemode is turned on
To disable SerDes tuning optimization on all backend ports and retain all current tuning values:
switch:admin> serdestunemode --autodisable
Autotunemode is turned off
switch:admin> serdestunemode --show
Autotunemode is turned off
To disable SerDes tuning optimization on all backend ports and reset all tuning values to their default
values:
switch:admin> serdestunemode --autoreset
AutoTune Resetting Default Tuning On Next Poll
switch:admin> serdestunemode --show
Autotunemode is in reset state
slotShow
Add the following text to the slotShow command (v7.0.0 and later):
FAULTY The blade is faulty because an error was detected. A fault code of 53 may also
indicate the possibility of a rolling reboot detection (RRD) on the specified blade.
In the case of an RRD, investigate and correct the cause, then reboot the control