Fabric OS Documentation Updates Supporting Fabric OS v7.0.x
Table Of Contents
- Contents
- About This Document
- Access Gateway Administrator’s Guide
- CEE Administrator’s Guide
- CEE Command Reference
- Fabric OS Administrator’s Guide
- Documentation updates for Fabric OS v7.0.0 and later
- Chapter 2, Performing Basic Configuration Tasks
- Chapter 4, Routing Traffic
- Chapter 5, Managing User Accounts
- Chapter 6, Configuring Protocols
- Chapter 7, Configuring Security Policies
- Chapter 9, Installing and Maintaining Firmware
- Chapter 12, Traffic Isolation Zoning
- Chapter 18, Administering Licensing
- Chapter 19, Monitoring Fabric Performance
- Chapter 20, Optimizing Fabric Behavior
- Chapter 22, Managing Long Distance Fabrics
- Chapter 23, Using the FC-FC Routing Service
- Documentation updates for Fabric OS v7.0.1 and later
- Documentation updates for Fabric OS v7.0.0 and later
- Fabric OS Command Reference
- Fabric OS Encryption Guide Supporting LKM
- Fabric OS Encryption Guide Supporting RKM
- Fabric OS Encryption Guide Supporting SKM and ESKM
- Fabric OS Encryption Guide Supporting TEMS
- Fabric OS Encryption Guide Supporting TEMS
- Fabric OS FCIP Administrator’s Guide
- Fabric OS FICON Administrator’s Guide
- Fabric OS Message Reference
- Fabric OS MIB Reference
- Fabric OS Troubleshooting and Diagnostics Guide
- Fabric Watch Administrator’s Guide
- Web Tools Administrator’s Guide
- Brocade DCX Backbone Hardware Reference Manual
- Brocade DCX-4S Backbone Hardware Reference Manual
Fabric OS Documentation Updates 75
53-1002165-10
Chapter
18
Brocade DCX Backbone Hardware Reference Manual
In this chapter
The updates in this chapter are for various hardware manuals.
•Chapter 5, Removal and Replacement Procedures . . . . . . . . . . . . . . . . . . . 75
Chapter 5, Removal and Replacement Procedures
All of the following occurs under the heading “Removal and replacement of the WWN card.”
Under the subheading “Determining the status of a WWN card” on page 73, replace the
information in Table 12 in the Sample error message column for the WWN unit is being faulted row
with the following information:
Before the subheading “Removing the WWN card and WWN bezel (logo plate)” on page 74, add the
following section:
Preparing for the WWN card replacement
If the WWN card requires replacement, complete the following steps.
ATTENTION
Follow ESD precautions (see “ESD Precautions” in your chassis manual).
1. Open a Telnet session to the chassis and log in to the active CP as admin. The default
password is “password”.
2. Verify that you are logged into the active CP. Run the haShow command to determine the active
CP.
3. Run the supportsave command on the active CP to capture all settings.
Type of message Sample error message
WWN unit is being faulted. <timestamp>, [EM-1034], <sequence-number>,,
ERROR,
<system-name>, WWN # set to faulty, rc=<return
code>
or
<timestamp>, [EM-1003], 40, SLOT 7 | FFDC |
CHASSIS, CRITICAL, Brocade_DCX, WWN 2 has unknown
hardware identifier: FRU faulted