Fabric OS Documentation Updates Supporting Fabric OS v7.0.x
Table Of Contents
- Contents
- About This Document
- Access Gateway Administrator’s Guide
- CEE Administrator’s Guide
- CEE Command Reference
- Fabric OS Administrator’s Guide
- Documentation updates for Fabric OS v7.0.0 and later
- Chapter 2, Performing Basic Configuration Tasks
- Chapter 4, Routing Traffic
- Chapter 5, Managing User Accounts
- Chapter 6, Configuring Protocols
- Chapter 7, Configuring Security Policies
- Chapter 9, Installing and Maintaining Firmware
- Chapter 12, Traffic Isolation Zoning
- Chapter 18, Administering Licensing
- Chapter 19, Monitoring Fabric Performance
- Chapter 20, Optimizing Fabric Behavior
- Chapter 22, Managing Long Distance Fabrics
- Chapter 23, Using the FC-FC Routing Service
- Documentation updates for Fabric OS v7.0.1 and later
- Documentation updates for Fabric OS v7.0.0 and later
- Fabric OS Command Reference
- Fabric OS Encryption Guide Supporting LKM
- Fabric OS Encryption Guide Supporting RKM
- Fabric OS Encryption Guide Supporting SKM and ESKM
- Fabric OS Encryption Guide Supporting TEMS
- Fabric OS Encryption Guide Supporting TEMS
- Fabric OS FCIP Administrator’s Guide
- Fabric OS FICON Administrator’s Guide
- Fabric OS Message Reference
- Fabric OS MIB Reference
- Fabric OS Troubleshooting and Diagnostics Guide
- Fabric Watch Administrator’s Guide
- Web Tools Administrator’s Guide
- Brocade DCX Backbone Hardware Reference Manual
- Brocade DCX-4S Backbone Hardware Reference Manual
76 Fabric OS Documentation Updates
53-1002165-10
Chapter 5, Removal and Replacement Procedures
18
4. Contact Brocade Technical Support for a replacement WWN card. Technical Support will
require the supportsave data collected in the previous step so that a replacement can be
programmed prior to shipping to your location.
DO NOT execute the frureplace command. The command will no longer be functional beginning
with the release of Fabric OS 7.0.0c, but users with earlier versions of the Fabric OS should
also NOT run the command.
Under the subheading “Removing the WWN card and WWN bezel (logo plate)” on page 82, replace
the steps with the following:
When the replacement WWN card has been received, complete the following steps to remove the
bezel and faulted WWN card.
ATTENTION
Follow ESD precautions (see “ESD Precautions” in your chassis manual).
1. Open a Telnet session to the chassis and log in to the active CP as admin. The default
password is “password”.
2. Verify that you are logged into the active CP. Run the haShow command to determine the active
CP.
3. Run the supportsave command on the active CP to capture all settings. If any problems occur
during the replacement, the information will be important for solving the problem.
4. Remove the screws from the WWN bezel. Pull the bezel away from chassis and set it aside. The
WWN cards are visible.
5. Use a Phillips screwdriver to unscrew the two screws that secure the WWN card to the chassis.
Hold the card by the edges and remove it.
6. Disconnect the WWN cable by depressing the cable connector latch and pulling the connector
from the WWN module.
7. Set the WWN card on a static-free surface, such as a grounding pad.
Under the subheading “Replacing the WWN bezel (logo plate) and WWN card” on page 83, delete
step 4.