Brocade Fabric OS Command Reference - Supporting Fabric OS v7.0.1 (53-1002447-01, March 2012)

766 Fabric OS Command Reference
53-1001764-01
portPerfShow
22
To display performance on a single port with at a 5 second interval:
switch:user> portperfshow 0 -t 5
0 Total
=================
630.4m 630.4m
0 Total
=================
630.3m 630.3m
(output truncated)
To display transmitter throughput for a single port at a 5 second interval:
switch:user> portperfshow 0 -tx -t 5
0
========
210.1m
0
========
210.1m
(output truncated)
To display receiver throughput for a single port at a 5 second interval:
switch:user> portperfshow 0 -rx -t 5
0
========
420.3m
0
========
420.2m
(output truncated)
To display port performance on a chassis for range of ports at an interval of 5 seconds:
switch:user> portperfshow 12/0-12/6 -t 5
0 1 2 3 4 5 6 Total
===============================================================
slot 12: 840.6m 0 0 0 0 0 630.4m 1.4g
0 1 2 3 4 5 6 Total
===============================================================
slot 12: 840.6m 0 0 0 0 0 630.4m 1.4g
0 1 2 3 4 5 6 Total
===============================================================
slot 12: 840.6m 0 0 0 0 0 630.4m 1.4g
(output truncated)
SEE ALSO portStatsShow