Brocade Fabric OS Command Reference - Supporting Fabric OS v7.0.1 (53-1002447-01, March 2012)

Fabric OS Command Reference 771
53-1001764-01
portShow
2
portType
The port's type and revision numbers.
POD Port
Port on Demand License status.
portState
The port's SNMP state:
Online
Up and running.
Offline
Not online, see portPhys for more detail.
Testing
Running diagnostics.
Faulty
Failed diagnostics.
Persistently Disabled
Persistently disabled.
Protocol
Protocol used by the port: FC or FCoE.
portPhys
The port's physical state:
No_Card
No interface card present.
No_Module
No module (GBIC or other) present.
No_Light
Module is not receiving light (Condor 2 ports only).
No_SigDet
No signal detected; displays when a quad small form-factor pluggables (QSFPs)
is installed without cables).
Mod_Inv
Incompatible vendor or module speed mismatch.
No_Sync
Receiving light but out of sync.
In_Sync
Receiving light and in sync.
Laser_Flt
Module is signaling a laser fault.
Port_Flt
Port marked faulty.
Diag_Flt
Port failed diagnostics.
Lock_Ref
Locking to the reference signal.
portScn
The port's last State Change Notification.
port generation number