Firmware upgrade and downgrade considerations
5
Do not try registering a node running Fabric OS 6.3.x or earlier to an encryption group when all
nodes are running Fabric OS 6.4.0(x) with one or more Fabric OS 6.4.0(x) features enabled.
Disable all Fabric OS 6.4.0(x) features before ejecting a node running Fabric OS 6.4.0(x) and
registering the node as a member of an encryption group with nodes running Fabric OS 6.3.x or
earlier.
Specific guidelines for HA clusters
The following are specific guidelines for a firmware upgrade of the encryption switch or blade when
deployed in HA cluster. The guidelines are based on the following scenario:
There are 2 nodes (BES1 and BES2) in the HA cluster.
Each node hosts certain number of CryptoTarget containers and associated LUNs.
Node 1 (BES1) needs to be upgraded first.
1. Change the failback mode to manual if it was set to auto by issuing the following command on
the group leader:
Admin:switch> cryptocfg --set -failbackmode manual
2. On node 1 (BES1), disable the encryption engine to force the failover of CryptoTarget
containers and associated LUNs onto the HA cluster peer member node 2 (BES2) by issuing
the following command.
Admin:switch> cryptocfg --disableEE
3. Ensure that these CryptoTarget Containers and LUNs actually fail over to node 2 (BES2) in the
HA cluster. Check for all LUNs in encryption enabled state on node 2 (BES2). This ensures that
I/O also fails over to node 2 (BES2) and continues during this process.
4. On node 1 (BES1) enable the encryption engine (EE), by issuing the following command.
Admin:switch> cryptocfg --enableEE
5. Start firmware download (upgrade) on the node 1 (BES1). Refer to the Fabric OS
Administrator’s Guide to review firmware download procedures.
6. After firmware download is complete and node 1 (BES1) is back up, make sure the encryption
engine is online.
7. On node 1 (BES1) initiate manual failback of CryptoTarget containers and associated LUNs
from node 2 (BES2) to node 1 (BES1) by issuing the following command.
Admin:switch> cryptocfg --failback -EE
8. Check that CryptoTarget Containers and associated LUNs fail back successfully on node 1
(BES1), and host I/O also moves from node 2 (BES2) to node 1 (BES1) and continues during
the failback process.
9. To upgrade node 2 (BES2), Repeat steps 2 to 8.
10. After all nodes in the Encryption Group have been upgraded, change back the failback mode to
auto from manual, if required, by issuing the following command.
Admin:switch> cryptocfg --set -failback auto