Brocade Fabric Watch Administrator's Guide v6.2.0 (53-1001188-01, April 2009)

40 Fabric Watch Administrator’s Guide
53-1001188-01
Class default settings
7
Environment class default settings
Table 10 provides default Environment class settings for all switches. Check the appropriate
hardware reference manual for differences in actual environmental requirements.
NOTE
Fabric Watch no longer supports fan monitoring. Event Manager (EM) now manages fan monitoring
and the switch status is calculated based on the fan status reported by EM.
TABLE 10 Environment class default settings
Area Description Default threshold
settings
Default alarm settings Threshold state
Temperature Monitors switch
temperature in
Celsius
Unit: degrees C
Time Base: none
Brocade 200E
Low: 0
High: 60
Buffer: 10
Changed: 0
Below: 3
Above: 3
In-Between: 3
(Same setting for all
devices)
Informative
Out-of-range
Out-of-range
In_range
(Same setting for all
devices except
Brocade DCX-4S)
Brocade 300
Low: 0
High: 40
Buffer: 10
Brocade 4100
Low:0
High: 60
Buffer: 10
Brocade 4900
Low: 0
High: 47
Buffer: 10
Brocade 5000
Low:0
High: 60
Buffer: 10
Brocade 5100
Low: 0
High: 35
Buffer: 10
Brocade 5300
Low: 0
High: 34
Buffer: 10
Brocade 7500
Low: 0
High: 63
Buffer: 10
Brocade 7600
Low: 0
High: 63
Buffer: 10