Brocade Fabric Watch Administrator's Guide v6.2.0 (53-1001188-01, April 2009)

Fabric Watch Administrator’s Guide 45
53-1001188-01
Class default settings
7
Port class default settings
Table 15 provides default settings (per minute) for areas in the Port class.
TABLE 15 Port class default settings
Area Description Default threshold
settings
Default alarm settings Threshold state
Invalid CRC Count Monitors the number
of CRC errors
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Invalid Transmission
Word
Monitors the number
of invalid words
transmitted
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Link Failure Count Monitors the number
of link failures
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Loss of Signal Count Monitors the number
of signal loss errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Loss of
Synchronization
Count
Monitors the number
of loss of
synchronization
errors
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Link Reset Monitors the number
of link resets sent by
a given port (LR-Out)
and received on a
given port (LR-In).
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Primitive Sequence
Protocol Error
Monitors the number
of primitive sequence
errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range