Brocade Fabric Watch Administrator's Guide v6.2.0 (53-1001188-01, April 2009)

50 Fabric Watch Administrator’s Guide
53-1001188-01
Class default settings
7
Resource class default settings
Table 18 provides default settings for areas in the Resource class.
Loss of Signal Count Monitors the number
of signal loss errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Link Reset Monitors the number
of link resets sent by
a given port (LR-Out)
and received on a
given port (LR-In).
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Primitive Sequence
Protocol Error
Monitors the number
of primitive sequence
errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
TABLE 18 Resource class default settings
Area Description Default threshold settings Default alarm settings Threshold state
Flash Monitors the
percentage of compact
flash used
Unit: Percentage (%)
Time base: none
Low: 0
High: 85
Buffer: 0
Changed: 0
Below: 3
Above: 3
In-Between: 1
Informative
Informative
Out_of_range
In_range
TABLE 17 F/FL_Port class default settings (Continued)
Area Description Default threshold
settings