Brocade Fabric Watch Administrator's Guide v6.2.0 (53-1001188-01, April 2009)

54 Fabric Watch Administrator’s Guide
53-1001188-01
Class default settings
7
SFP class default settings
Table 20 provides default settings for areas in the SFP class.
NOTE
SFPs connected to GbE ports are not monitored.
TABLE 20 SFP class default settings
Area Description Default threshold settings Default alarm settings Threshold state
Current Monitors SFP current Unit: mA
Time Base: none
Low: 0
High: 50
Buffer: 1
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Receive Power Monitors receive power
in µWatts
Unit: µWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Supply Voltage Monitors SFP electrical
force in volts
Unit: mV
Time Base: none
Low: 3150
High: 3600
Buffer: 10
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Temperature Monitors SFP
Temperature
Unit: Degrees C
Time Base: none
Low: -10
High: 85
Buffer: 3
Changed: 0
Below: 1
Above: 1
In-Between: 1
Informative
Out_of_range
Out_of_range
Normal
Transmit Power Monitors transmit
power in µWatts
Unit: µWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Normal