Brocade Fabric Watch Administrator's Guide v6.2.0 (53-1001188-01, April 2009)

62 Fabric Watch Administrator’s Guide
53-1001188-01
Threshold configuration
8
3. Type the number from the list that corresponds to the class that you want to configure. Select 3
for Port class, 5 for E_Port class, or 6 for F/FL Port (Optical) class.
For each class that you select, Fabric Watch provides a list of the areas of the class available
for configuration.
4. Select an area (areas 1 - 2 and 4 - 6 are available for Port Fencing).
1 : Link loss (E-port)
2 : Sync loss (E-port)
3 : Signal loss (E-port)
4 : Protocol error (E-port)
5 : Invalid words (E-port)
6 : Invalid CRCS (E-port)
7 : RXPerformance(E-port)
8 : TXPerformance (E-port)
9 : State Changes (E/VE-port)
10 : Link reset (E-port)
11 : Utilization (VE-port)
12 : Packet loss (VE-port)
13 : return to previous page
Select an area => : (1..2) (4..6) [10] 1
In this example, if you type 1, the menu corresponding to the Link loss displays.
See Chapter 3, “Fabric Watch components” for more details about classes and areas.
5. Select advanced configuration by typing 4 at the Select choice prompt.
1 : refresh
2 : disable a threshold
3 : enable a threshold
4 : advanced configuration
5 : return to previous page
Select an area => : (1..5) [5] 4
6. Select change above alarm by typing 14 at the Select choice prompt.
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change below alarm
4 : change custom unit 14 : change above alarm
5 : change custom time base 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18] 14
7. Set the alarm for Port Fencing (32) by typing 32 at the Enter above alarm matrix prompt.
Errlog-1, SnmpTrap-2, PortLogLock-4
RapiTrap-8, EmailAlert-16, PortFencing-32
Valid alarm matrix is 63
Enter above alarm matrix => : (0..63) [0] 32