Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

Fabric OS Message Reference 65
53-1000600-01
BM-1007
7
BM-1007
Message <timestamp>, [BM-1007], <sequence-number>,, INFO, <system-name>, Clearing
EX/VEX/FC port configuration for all ports for blade in slot
<Slot number>.
Probable Cause The specified blade was detected for the first time after an FR4-18i was previously configured in
the same slot. The new blade requires the specified port configurations to be cleared.
Recommended
Action
The blade ports are cleared automatically. No action is required.
Severity INFO
BM-1008
Message <timestamp>, [BM-1008], <sequence-number>,, WARNING, <system-name>, Download of
blade firmware failed for blade in slot
<slot>. Reissue firmwaredownload to
recover.
Probable Cause The automatic firmware upgrade on the blade has failed because the blade firmware version was
detected to be different from the control processor (CP) firmware version.
Recommended
Action
Issue the firmwareDownload command to recover the blade.
Severity WARNING
BM-1009
Message <timestamp>, [BM-1009], <sequence-number>,, WARNING, <system-name>,
Firmwaredownload timed-out for application processor. Faulting switch.
Probable Cause The firmwareDownload on the application processor (AP) blade failed.
Recommended
Action
Use the slotPowerOff and slotPowerOn commands or reseat the affected blade. On the Brocade
7500 or 7600, switch off and on all primary power in order to power-cycle the unit.
Severity WARNING
BM-1010
Message <timestamp>, [BM-1010], <sequence-number>,, INFO, <system-name>, Resetting port
configuration and linkcost for all ports for blade in slot <Slot number>.
Probable Cause The specified blade was detected for the first time after an FC10-6 was previously configured in the
same slot. The new blade requires resetting the port configuration and linkcost.
Recommended
Action
The blade ports are cleared automatically. No action is required.