Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

80 Fabric OS Message Reference
53-1000600-01
EM-1009
12
EM-1009
Message <timestamp>, [EM-1009], <sequence-number>, FFDC, CRITICAL, <system-name>, <FRU
Id>
powered down unexpectedly.
Probable Cause Indicates that the environmental monitor (EM) received an unexpected power-down notification
from the specified field-replaceable unit (FRU). This might indicate a hardware malfunction in the
FRU.
Recommended
Action
Try reseating the FRU. If the message persists, replace the FRU. Refer to the Brocade 48000
Hardware Reference Manual for more information about chassisConfig modes and supported
blades.
Severity CRITICAL
EM-1010
Message <timestamp>, [EM-1010], <sequence-number>, FFDC, CRITICAL, <system-name>,
Received unexpected power down for <FRU Id> But <FRU Id> still has power.
Probable Cause Indicates that the environmental monitor (EM) received an unexpected power-down notification
from the specified field-replaceable unit (FRU). However, the specified FRU still appears to be
powered up after four seconds.
Recommended
Action
Try reseating the blade. If this fails to correct the error, replace the blade.
Severity CRITICAL
EM-1011
Message <timestamp>, [EM-1011], <sequence-number>, FFDC, CRITICAL, <system-name>,
Received unexpected power down for
<FRU Id>, but cannot determine if it has
power.
Probable Cause Indicates that the environmental monitor (EM) received an unexpected power-down notification
from the field-replaceable unit (FRU) specified; however, after four seconds it cannot be
determined if it has powered down or not.
Recommended
Action
Try reseating the blade. If this fails to correct the error, replace the blade.
Severity CRITICAL