Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

Fabric OS Message Reference 113
53-1000600-01
FABS-1013
16
FABS-1013
Message <timestamp>, [FABS-1013], <sequence-number>,, ERROR, <system-name>, <Method
name>[<Method tag number>]:Unknown blade type 0x<Blade type>
Probable Cause An unrecognized type of blade has been discovered in the system.
This may be caused by an incorrect FRU header, inability to read the FRU header, or the blade may
not be supported by this platform or Fabric OS version.
Recommended
Action
Verify that the blade is valid for use in this system and this version of Fabric OS.
Try reseating the blade.
If this is a valid blade and reseating does not fix the problem, then replace the blade.
Severity ERROR
FABS-1014
Message <timestamp>, [FABS-1014], <sequence-number>,, ERROR, <system-name>, <Method
name>[<Method tag number>]:Unknown FRU type 0x<FRU Object type>
Probable Cause An unrecognized type of FRU has been discovered in the system.
This may be caused by an incorrect FRU header, inability to read the FRU header, or the FRU may
not be supported by this platform or Fabric OS version.
Recommended
Action
Verify that the FRU is valid for use in this system and this version of Fabric OS.
Try reseating the FRU.
If this is a valid FRU and reseating doesn't help, then replace the FRU.
Severity ERROR
FABS-1015
Message <timestamp>, [FABS-1015], <sequence-number>,, ERROR, <system-name>, <Method
name>[<Method tag number>]:Request to enable FRU type 0x<FRU Object type>, unit
<Unit number> failed. err code <Error code>
Probable Cause Indicates the specified FRU could not be enabled. This is usually an internal Fabric OS problem.
Recommended
Action
Try removing and reinserting the FRU.
Reboot or power-cycle the CP or system.
If the message persists, run the firmwareDownload command to update the firmware.
Severity ERROR