Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

Fabric OS Message Reference 115
53-1000600-01
Chapter
17
FBC System Messages
FBC-1001
Message <timestamp>, [FBC-1001], <sequence-number>,, ERROR, <system-name>, Firmware
version on AP blade is incompatible with that on the CP.
Probable Cause The CP determined that the version of firmware running on the AP blade is not compatible with the
version of firmware running on the CP. The AP and CP blades cannot communicate.
Recommended
Action
The problem can be corrected by changing the version of firmware on the CP or AP blades. The
firmware version on the CP blade can be changed using the firmwareDownload command. Refer to
the release notes to determine whether a non-disruptive firmwareDownload is supported between
the versions. As the AP and CP blades cannot communicate, it is not possible to load new firmware
on the AP blade. If required, send the AP blade back to the factory to get a new firmware version
installed.
Severity ERROR