Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

134 Fabric OS Message Reference
53-1000600-01
FICN-1033
22
Probable Cause The XRC System Data mover was restarted to discover the capabilities of the channel extension
equipment.
Recommended
Action
No action is required. This is a part of the XRC initialization.
Severity INFO
FICN-1033
Message <timestamp>, [FICN-1033], <sequence-number>,, INFO, <system-name>,
HostEgr:Logical Path Established on Path=<FICON PATH>.
Probable Cause The peer side FICON Control Unit has accepted a logical path establishment command sequence
with the FICON channel.
Recommended
Action
No action is required. This is a part of the FICON path initialization.
Severity INFO
FICN-1034
Message <timestamp>, [FICN-1034], <sequence-number>,, ERROR, <system-name>,
HostEgr:Discarding Invalid LRCd Frame on Path=<FICON PATH> count=<The total number
of frames that have been received with an invalid LRC>.
Probable Cause The channel emulation processing received a frame with an invalid FICON LRC from the peer. This
indicates that the channel side noted corruption from the device/CU side processing.
Recommended
Action
Please contact your vendor's customer support for assistance.
Severity ERROR
FICN-1035
Message <timestamp>, [FICN-1035], <sequence-number>,, WARNING, <system-name>,
HostIng:FICON System Reset received on Path=<FICON PATH>.
Probable Cause A locally connected FICON channel issued a System Reset to the specified FICON Control Unit.
Recommended
Action
No action is required. This is a part of the FICON path initialization.
Severity WARNING