Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

136 Fabric OS Message Reference
53-1000600-01
FICN-1040
22
FICN-1040
Message <timestamp>, [FICN-1040], <sequence-number>,, ERROR, <system-name>,
HostTapeEgr:Tape:CmdReject Sense Data Rcvd:Path=<FICON PATH> LastCmds=0x<Last 4
commands received from the channel for this device> SenseData:Bytes0-0xB=0x<FICON
device Sense Data bytes 0-11>.
Probable Cause An active disk emulation device received a FICON Purge Path from the channel.
Recommended
Action
If there was an unexpected job failure or IO Error associated with this event, please contact your
vendor's customer support for assistance.
Severity ERROR
FICN-1041
Message <timestamp>, [FICN-1041], <sequence-number>,, ERROR, <system-name>,
HostTapeEgr:AS Link Level Reject (LRJ) from CU Rx Path=<FICON PATH>
LastCmd=0x<Last 4 commands issued to this device from the channel>
LastStatus=0x<Last 4 status values sent to the channel from this device>.
Probable Cause An LRJ received from a device indicates that the CU has lost the logical path to the LPAR.
Recommended
Action
If this was an unexpected event, please contact your vendor's customer support for assistance.
Severity ERROR
FICN-1042
Message <timestamp>, [FICN-1042], <sequence-number>,, WARNING, <system-name>,
HostTapeIng:FICON Cancel received Path=<FICON PATH> state=0x<the current
emulation state for this device>.
Probable Cause A job was cancelled during write
pipelining.
Recommended
Action
If this was an unexpected event (cancel is normally an operator event), please contact your
vendor's customer support for assistance.
Severity WARNING
FICN-1043
Message <timestamp>, [FICN-1043], <sequence-number>,, ERROR, <system-name>,
HostTapeIng::FICON Selective Reset:Path=<FICON PATH> state=0x<the current
emulation state for this device> LastCmds=0x<the last 4 commands received from the
channel for this device> LastStatus=0x<the last 4 status values presented to the
channel for this device>.