Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

144 Fabric OS Message Reference
53-1000600-01
FICN-1070
22
Probable Cause An error has been noted in the FICON configuration. Please refer to the string for the nature of the
configuration issue.
Recommended
Action
If resolution of the configuration issue cannot be completed, please contact your vendor's
customer support for assistance.
Severity ERROR
FICN-1070
Message <timestamp>, [FICN-1070], <sequence-number>,, INFO, <system-name>,
DevTapeIngr:Exceptional Status rcvd on Path=<FICON PATH> state=0x<current
emulation state> status=0x<the exceptional status value>.
Probable Cause The normal end of tape status (0x0D or 0x05) is received from the device or error status (including
Unit Check 0x02) is received from an active emulation device.
Recommended
Action
The end of tape is a normal event during pipelining and not the unit check. If there are associated
IO error messages with this event, please contact your vendor's customer support for assistance.
Severity INFO
FICN-1071
Message <timestamp>, [FICN-1071], <sequence-number>,, INFO, <system-name>,
HostTapeIngr:Tape Loaded on Path=<FICON PATH>.
Probable Cause Tape IOs are processed from a locally connected LPAR, which indicates that a tape is loaded on a
device.
Recommended
Action
No action is required.
Severity INFO
FICN-1072
Message <timestamp>, [FICN-1072], <sequence-number>,, INFO, <system-name>,
DevTapeEgr:Tape Loaded on Path=<FICON PATH>.
Probable Cause Tape IOs are processed from a locally connected LPAR, which indicates that a tape is loaded on a
device.
Recommended
Action
No action is required.
Severity INFO