Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

148 Fabric OS Message Reference
53-1000600-01
FICN-1082
22
FICN-1082
Message <timestamp>, [FICN-1082], <sequence-number>,, WARNING, <system-name>,
EmulEls:CSWR_RSCN received on GEPort=<GEPortNumber> VEPort=<VEPortNumber>
Domain=0x<Domain Port Host> Port=0x<Device Side>.
Probable Cause An attached port which had an FICON emulated path established has logged out from the switch.
Recommended
Action
This may be an unexpected event, please contact your vendor's customer support for assistance.
Severity WARNING
FICN-1083
Message <timestamp>, [FICN-1083], <sequence-number>,, WARNING, <system-name>,
EmulEls:SW_RSCN received on GEPort=<GEPortNumber> VEPort=<VEPortNumber>
Domain=0x<Domain Port Host> Port=0x<Device Side>.
Probable Cause An attached port with the established FICON emulated path has logged out from the switch.
Recommended
Action
This may be an unexpected event, please contact your vendor's customer support for assistance.
Severity WARNING
FICN-1084
Message <timestamp>, [FICN-1084], <sequence-number>,, ERROR, <system-name>, fcFicInit: No
DRAM2 memory available, FICON emulation is disabled.
Probable Cause A faulty DRAM2 was detected and access to its address range is prohibited.
Recommended
Action
This is an unexpected event, please contact your vendor's customer support for assistance.
Severity ERROR
FICN-1085
Message <timestamp>, [FICN-1085], <sequence-number>,, INFO, <system-name>, FICON FCIP
Tunnel is Up on GE<Either GE0 or GE1>,tunnel Id=<The configured tunnel ID (0-7)>.
Probable Cause A FICON FCIP tunnel has been established successfully to the peer switch.
Recommended
Action
No action is required.
Severity INFO