Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

288 Fabric OS Message Reference
53-1000600-01
ISNS-1004
42
ISNS-1004
Message <timestamp>, [ISNS-1004], <sequence-number>,, WARNING, <system-name>, Timeout
refreshing iSNS database with iSNS server <iSNS server IP address> slot/port <Slot
number>/ge<Port number> Reg-Period <Registration-Period in seconds>.
Probable Cause Indicates that the internet storage name service (iSNS) client failed to receive a successful
response for a DevAttrQry within the specified Registration-Period.
Recommended
Action
Verify the connection of the iSNS server to the slot/port.
Severity WARNING
ISNS-1005
Message <timestamp>, [ISNS-1005], <sequence-number>,, INFO, <system-name>, User request
re-register with external iSNS server <iSNS server IP address> slot/port <Slot
number>/ge<Port number>.
Probable Cause Indicates that the user has requested a re-register with the specified external internet storage
name service (iSNS) server.
Recommended
Action
No action is required.
Severity INFO
ISNS-1006
Message <timestamp>, [ISNS-1006], <sequence-number>,, INFO, <system-name>, Start
re-register with external iSNS server <iSNS server IP address> slot/port <Slot
number>/ge<Port number>.
Probable Cause Indicates that the re-register with the specified external internet storage name service (iSNS)
server has started.
Recommended
Action
No action is required.