Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

Fabric OS Message Reference 325
53-1000600-01
Chapter
51
MS System Messages
MS-1001
Message <timestamp>, [MS-1001], <sequence-number>,, WARNING, <system-name>, MS Platform
Segmented port=<port number>(<reason for segmentation> <domain>)
Probable Cause Indicates that the management server (MS) has segmented from another switch domain at the
specified port number due to errors or inconsistencies defined in the MS platform service.
Recommended
Action
Reboot or power cycle the switch.
Severity WARNING
MS-1002
Message <timestamp>, [MS-1002], <sequence-number>,, INFO, <system-name>, MS Platform
Service Unstable(
<message string><domain number>)
Probable Cause The management server (MS) platform service is unstable.
The message string can be one of the following:
<No Resp for GCAP from>
The switch did not respond to a request for GCAP (MS Get Capabilities) command.
Recommended Action: No action is required.
<GCAP sup but not PL by>
The GCAP (MS Get Capabilities) is supported but the flag for MS platform service is not set.
Recommended Action: Set the flag for the MS Platform Service.
<GCAP Rejected (reason =BUSY) by>
The GCAP (MS Get Capabilities) is not supported by another switch.
Recommended Action: Upgrade the firmware level on the switch to a level that supports RCS.
<Reject EXGPLDB from>
The request to the exchange platform database was rejected. The remote switch might be
busy.
Recommended Action: Wait a few minutes and try the command again.
The domain number is the target domain that caused error.
Recommended
Action
The recommended actions are as follows:
<No Resp for GCAP from>
No action is required.
<GCAP sup but not PL by>
Set the flag for the MS Platform Service.