Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

Fabric OS Message Reference 327
53-1000600-01
MS-1005
51
Severity INFO
MS-1005
Message <timestamp>, [MS-1005], <sequence-number>,, ERROR, <system-name>, MS Invalid CT
Response from d=
<domain>
Probable Cause Indicates that the management server (MS) received an invalid common transport (CT) response
from switch domain. MS expects either a CT accept IU or a reject IU; MS received neither response,
which violates the Fibre Channel Generic Services (FS-GS) specification.
Recommended
Action
Check the integrity of the FC switch at the specified domain. It is not sending correct MS
information as defined by the FC-FS standard.
Severity ERROR
MS-1006
Message <timestamp>, [MS-1006], <sequence-number>,, ERROR, <system-name>, MS Unexpected
iu_data_sz=
<number of bytes>
Probable Cause Indicates that management server (MS) received information unit (IU) data of unexpected size. The
IU payload and the IU size might be inconsistent with each other or with the command that is
currently being processed.
Recommended
Action
Wait a few minutes and try the operation again.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
MS-1008
Message <timestamp>, [MS-1008], <sequence-number>,, ERROR, <system-name>, MS Failure
while initializing
<action>
Probable Cause The management server (MS) failed while initializing the specified action.
The following actions might be displayed:
<while writing to ms_els_q>
MS is unable to write a message to the MS Extended Link Service Queue.
<while inserting timer to timer list>
MS is unable to add a timer to a resource.
Recommended
Action
This message is often transitory.
If the message persists, check the available memory on the switch using memShow.
Severity ERROR