Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

Fabric OS Message Reference 349
53-1000600-01
Chapter
58
PS System Messages
PS-1000
Message <timestamp>, [PS-1000], <sequence-number>, FFDC, CRITICAL, <system-name>, Failed
to initialize Advanced Performance Monitoring.
Probable Cause Indicates that an unexpected software error has occurred in Advanced Performance Monitoring.
The Performance Monitor has failed to initialize.
Recommended
Action
The CP should reboot (or fail over) automatically. If it does not, reboot or power cycle the switch to
reinitiate the firmware.
Severity CRITICAL
PS-1001
Message <timestamp>, [PS-1001], <sequence-number>,, INFO, <system-name>, Advanced
Performance Monitoring configuration updated due to change in PID format
Probable Cause Indicates that the PID format was changed.
Recommended
Action
No action is required. Refer to the Fabric OS Administrator’s Guide for more information about the
PID format.
Severity INFO
PS-1002
Message <timestamp>, [PS-1002], <sequence-number>,, INFO, <system-name>, Failed to
initialize the tracing system for Advanced Performance Monitoring.
Probable Cause Indicates that an unexpected software error has occurred in Advanced Performance Monitoring.
The Performance Monitor tracing system has failed to initialize.
Recommended
Action
Tracing will not be available for Advanced Performance Monitoring, but other functions should
function normally. To retry activating tracing, reboot (or fail over) the CP.
Severity INFO