Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

Fabric OS Message Reference 379
53-1000600-01
SEC-1046
66
SEC-1046
Message <timestamp>, [SEC-1046], <sequence-number>,, ERROR, <system-name>, Empty list.
Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR
SEC-1049
Message <timestamp>, [SEC-1049], <sequence-number>,, ERROR, <system-name>, Invalid switch
name
<switch name>.
Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR
SEC-1050
Message <timestamp>, [SEC-1050], <sequence-number>,, ERROR, <system-name>, There are more
than one switches with the same name
<switch name> in the fabric.
Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR