Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

Fabric OS Message Reference 429
53-1000600-01
Chapter
67
SNMP System Messages
SNMP-1001
Message <timestamp>, [SNMP-1001], <sequence-number>,, ERROR, <system-name>, SNMP service
is not available
<Reason>.
Probable Cause Indicates that the simple network management protocol (SNMP) service could not be started
because of the specified Reason. You will not be able to query the switch through SNMP.
Recommended
Action
Verify that the IP address for the Ethernet and Fibre Channel interface is set correctly. If the
specified Reason is an initialization failure, the switch requires a reboot.
Severity ERROR
SNMP-1002
Message <timestamp>, [SNMP-1002], <sequence-number>,, ERROR, <system-name>, SNMP <Error
Details>
initialization failed.
Probable Cause Indicates that the initialization of the simple network management protocol (SNMP) service failed
and you will not be able to query the switch through SNMP.
Recommended
Action
Reboot or power cycle the switch. This will automatically initialize SNMP.
Severity ERROR
SNMP-1003
Message <timestamp>, [SNMP-1003], <sequence-number>,, ERROR, <system-name>, Distribution
of Community Strings to Secure Fabric failed.
Probable Cause Indicates that the changes in the simple network management protocol (SNMP) community strings
could not be propagated to other switches in the secure fabric.
Recommended
Action
Retry changing the SNMP community strings from the primary switch.
Severity ERROR