Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

442 Fabric OS Message Reference
53-1000600-01
SULB-1018
69
Probable Cause Indicates that firmwareDownload failed in the specified blade. The error may be caused by an
inconsistent AP blade firmware stored on the active CP. It may also caused by an internal Ethernet
issue or by a persistent storage hardware failure.
Recommended
Action
Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and
slotPowerOn commands to trigger another firmwareDownload. If the blade is stuck in LOADING
state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists,
contact your switch service provider.
Severity ERROR
SULB-1018
Message <timestamp>, [SULB-1018], <sequence-number>, AUDIT, ERROR, <system-name>,
Firmwaredownload timed out in slot
<Slot number>.
Probable Cause The error may be caused by a blade initialization issue after the new firmware is downloaded and
the blade is rebooted. The error may also be caused by an internal Ethernet issue or by a persistent
storage failure.
Recommended
Action
Run the slotShow command. If the blade is in FAULTY state, run the slotPowerOff and slotPowerOn
commands to trigger another firmwareDownload. If the blade is stuck in LOADING state, remove
and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your
switch service provider.
Severity ERROR
SULB-1020
Message <timestamp>, [SULB-1020], AUDIT, ERROR, <system-name>, New firmware failed to boot
in slot
<Slot number>.
Probable Cause The BP blade should reboot with the new image, but is still running the old image. This error may
indicate that the new image has not been loaded correctly to the specified blade.
Recommended
Action
Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and
slotPowerOn commands to trigger another firmwareDownload to the blade. If the blade is stuck in
LOADING state, remove and re-insert the blade to trigger another firmwareDownload. If the problem
persists, contact your switch service provider.
Severity ERROR
SULB-1021
Message <timestamp>, [SULB-1021],<sequence-number>, AUDIT, WARNING, <system-name>,
Firmware is being downloaded to the blade in slot
<Slot number>.
Probable Cause Indicates that the firmware is being loaded to the indicated blade.