Fabric OS Message Reference 445
53-1000600-01
SULB-1033
69
Probable Cause Indicates that the switch has rebooted with the new firmware and is relocating the AP firmware.
Recommended
Action
Wait for the operation to complete.
Severity WARNING
SULB-1033
Message <timestamp>, [SULB-1033], <sequence-number>, AUDIT, WARNING, <system-name>,
Switch has completed relocating the internal firmware image.
Probable Cause Indicates that the firmwareDownload process has completed normally on the switch.
Recommended
Action
Run the firmwareShow command to verify the firmware versions. Run the switchShow command to
make sure the switch is enabled.
Severity WARNING
SULB-1034
Message <timestamp>, [SULB-1034], <sequence-number>, AUDIT, ERROR, <system-name>,
Firmwaredownload timed out.
Probable Cause The error may be caused by a switch initialization issue after the internal image is relocated. It may
also be caused by an internal Ethernet issue or by persistent storage failure.
Recommended
Action
Reboot the switch. This will cause the internal image to be relocated again. Use the
firmwareDownloadStatus to monitor the progress. If the problem persists, contact your switch
service provider.
Severity ERROR
SULB-1035
Message <timestamp>, [SULB-1035], <sequence-number>, AUDIT, ERROR, <system-name>, An
error has occurred during relocation of the internal image.
Probable Cause Indicates that an error has occurred during the relocation of the internal image. The error may be
caused by inconsistent internal firmware image. It may also be caused by the internal Ethernet or
persistent storage hardware failure.
Recommended
Action
Reset the switch. This will cause the internal image to be relocated again. If the problem persists,
contact your switch service provider.
Severity ERROR